Corrosion Protection

INSTITUTEs

The range of services of the research center includes the investigation of corrosion resistance of metallic and non-metallic coatings as well as components and products made of stainless steel.  Our Laboratory provides modern test facilities, such as a salt-spray-testing-machine and a corrosion meter for cyclic testing.

 

Further information regarding the testing machines can be found here and here.

 

 

Prediction of long-term corrosion resistance of:

 

  • Materials and material connections
  • Metallic Coatings
  • Other Coatings
  •  

The MPA University of Stuttgart operates outdoor exposure testing set-ups and laboratories in which the influence of all relevant environmental conditions and atmospheres can be investigated over many years.

 

Sea water test (Offshore area / corrosivity category C5-M, CX according to ISO 9223 respectively) with the test areas:

 

  • Splash water zone
  • Alternate immersion zone
  • Submerge zone
  •  

Atmospheric test facility:

 

  • Stuttgart (corrosivity category C2 according to DIN EN ISO 12944-2)
  • Duisburg (corrosivity category C3 – C4 according to DIN EN ISO 12944-2)
  • Helgoland (corrosivity category C4 – C5-M according to DIN EN ISO 12944-2)

www.mpa.uni-stuttgart.de

 

Ansprechpartnerin:

Dr.-Ing. Anne Jüngert

anne.juengert@mpa.uni-stuttgart.de

 

left - Atmospheric test facility; right – Sea water test facility in Heligoland Images: MPA Stuttgart